What is the difference between air-cooled module units and conventional chillers

Update:05 Aug 2019
Summary:

Since the first air-cooled module unit was put into use […]

Since the first air-cooled module unit was put into use in Asia, Melbourne, in September 1986, it has now spread to many countries around the world. It consists of multiple small chiller units in parallel, each chiller unit becomes a module, each module consisting of one or several independent refrigeration systems. The unit can provide 5-8 °C constant temperature water for industrial or building air conditioning. So, what is the difference between the air-cooled module unit and the conventional chiller? Let's take a look at the introduction of the stellar chiller manufacturer Xiaobian.

What is the difference between air-cooled module units and conventional chillers? Xiao Bian has been engaged in air-cooled module units for more than 20 years. Here are some of the characteristics of air-cooled module units:

  1. Computer control, high degree of automation and intelligence. The computer detection and control system in the unit according to the external load, timely start and stop the various modules of the shutdown group, comprehensively coordinate and control the dynamic operation of the entire chiller, and can record the operation of the unit, so there is no need to set up a dedicated person.

2, can make the cooling capacity of the chiller and the external load synchronously increase and decrease and the best match, the unit operating efficiency is high, saving energy. (For more information, please pay attention to the public number: Anhui Hengxing Century Air Conditioning Refrigeration Equipment Co., Ltd.)

3. During the operation of the modular unit, if the external load is abrupt or a refrigeration system fails, the computer control can automatically make each refrigeration system run in a step-by-step manner, and enable the backup refrigeration system to improve the whole. The reliability of the unit.

4. Each module unit in the unit is small in size, compact in structure, flexible in assembly, effective in utilizing space, saving floor space and installation cost.

5. The unit adopts the unitized design of the combined module, and can form a unit with different cooling capacity by using different modular units, and the range of selectable cooling capacity is wide. Especially in the renovation project, according to the engineering needs, only a few units can be connected in parallel within the allowable combination of the units.