HANBELL Low Temperature Air-Cooled Condensing Unit

HANBELL Low Temperature Air-Cooled Condensing Unit

Advantages:

1.Equipped with updated 5:6 asymmetric rotor semi-hermetic screw compressor, which provides with high efficiency, long life, small vibration and low noise

2.With multi-level energy regulation, energy can be adjusted according to the change of cooling load, which can effectively reduce energy consumption

3.The unit has multi-protection for compressor coil temperature, exhaust temperature, low oil level, oil pressure difference and high-low pressure of the system.

Details

Main Parts:

●Screw compressor●Sub oil●Sub oil outlet ball valve ●Oil return sight glass ●Condenser(Only for water cooling unit)●Reservoir (Only for air cooling unit) ●Filter barrel ●Sight glass ●Spray system ●economizer system ●Oil pressure differential protector  ●High-low pressure protector  ●Pressure gauge ●High pressure control(Control cooling tower or condenser fan) ●Low pressure sensor(Adjustable) ●Control box(PLC+/Touch pad)

Main tech parameters:

Remark: Below parameters are based on Refrigerant R22, please contact us for more details if any other kinds of refrigerants used.

Type

HLGF

30L

40L

50L

60L

70L

80L

90L

Compressor type

Type

RC2-100B

RC2-140B

RC2-180B

RC2-230B

RC2-260B

RC2-310B

RC2-340B

Style

Semi-hermetic screw compressor

Energy adjustment

66%-100%

50%-75%-100%

Cooling capacity and power

Evaporation -20℃

Cooling capacity(KW)

38.7

54

70.6

97.9

101.3

126.2

141

Power(KW)

24

30.7

38.5

53.5

55.1

67.6

73

Evaporation -25℃

Cooling capacity(KW)

31.3

43.6

57.1

79.2

82

102.1

114.2

Power(KW)

23.6

29.6

37.2

51.6

53.2

65.3

70.5

Evaporation -30℃

Cooling capacity(KW)

24.8

34.5

45.1

62.6

64.8

80.8

90.4

Power(KW)

22.4

27.8

35.8

49.8

51.3

62.9

67.9

Storage temperature( ℃)

-20~-15℃

Refrigerant

R22

Power supply

380V/3P/50Hz

Max operation current (A)

69

91

121

158

171

203

220

Port

Inhale port(mm)

Φ54

Φ54

Φ67

Φ76

Φ76

Φ76

Φ108

Liquid inlet port(mm)

Φ28

Φ28

Φ35

Φ35

Φ35

Φ35

Φ42

Exhaust port(mm)

Φ42

Φ42

Φ42

Φ54

Φ54

Φ54

Φ67

Liquid inlet port(mm)

Φ35

Φ35

Φ35

Φ35

Φ35

Φ35

Φ54

Boundary dimensions

A (mm)

1730

1730

2300

2300

2300

2600

2600

B (mm)

700

700

700

770

770

850

850

C (mm)

1100

1100

1100

1250

1250

1400

1400

Installation dimension (a×b)(mm)

1000×390

1000×390

1200×390

1200×390

1200×390

1500×500

1500×500

Unit design condition: evaporation temperature -23℃,environment temperature 35℃, running with economizer.

Type

HLGF

100L

110L

125L

130L

140L

150L

Compressor type

Type

RC2-370B

RC2-410B

RC2-470B

RC2-510B

RC2-550B

RC2-580B

Style

Semi-hermetic screw compressor

Energy adjustment

50%-75%-100%

Cooling capacity and power

Evaporation -20℃

Cooling capacity(KW)

152.6

164.6

200.1

209

234.8

250.5

Power(KW)

78.9

87.2

100.8

108

118.8

127.9

Evaporation -25℃

Cooling capacity(KW)

123.6

133.2

162.1

169.3

190.2

202.9

Power(KW)

76.1

84.2

97.2

104.3

114.7

123.4

Evaporation -30℃

Cooling capacity(KW)

97.9

105.4

128.5

134

150.7

160.7

Power(KW)

73.4

81.2

93.8

100.5

110.6

119

Storage temperature( ℃)

-20~-15℃

Refrigerant

R22

Power supply

380V/3P/50Hz

Max operation current (A)

241

268

310

336

355

377

Port

Inhale port(mm)

Φ108

Φ108

Φ108

Φ108

Φ108

Φ108

Liquid inlet port(mm)

Φ42

Φ42

Φ42

Φ42

Φ42

Φ42

Exhaust port(mm)

Φ67

Φ67

Φ67

Φ76

Φ76

Φ76

Liquid inlet port(mm)

Φ54

Φ54

Φ54

Φ54

Φ54

Φ54

Boundary dimensions

A (mm)

2600

2750

2750

3050

3050

3050

B (mm)

850

870

870

870

870

870

C (mm)

1400

1450

1450

1450

1450

1450

Installation dimension (a×b)(mm)

1500×500

1500×600

1500×600

1800×600

1800×600

1800×600

Unit design condition: evaporation temperature -23℃,environment temperature 35℃, running with economizer

Figure of boundary dimensions and installation dimensions: 

33

CONTACT WITH US
  • captcha